| 1. Disconnect the battery from weight. |
| Firm Bosch generator |
|
2. Remove a regulator and check up length of brushes which should be not less than 6 mm. |
| 3. If necessary replace brushes which fasten the screw or the soldering (to solder no more than 5 сек). |
| Firm Motorola generator |
| 4. Remove the generator. |
| 5. Turn away screws and remove a regulator and щеткодержатель. |
| 6. Check up length of brushes which should be not less than 6 mm. Brushes vary in the complete set. |