Toyota 4 Runner/Hilux/Surf

1987-1998 of release

Repair and car operation



Тойота 4Раннер
+ 1. The maintenance instruction
+ 2. Maintenance service
+ 3. Engines
- 4. Systems of heating, ventilation
   4.1. Specifications
   4.2. Antifreeze
   4.3. The thermostat
   4.4. Крыльчатка the fan and гидромуфта
   4.5. A radiator and a tank
   4.6. Маслоохладитель
   - 4.7. The pump
      4.7.1. Check
      4.7.2. Removal and installation
   4.8. The gauge of temperature of a liquid
   4.9. The electric motor and a chain of the fan of a heater
   4.10. A heater radiator
   4.11. The control panel the air-conditioning block
   + 4.12. A central air
   4.13. The compressor
+ 5. Fuel and exhaust systems
+ 6. Transmissions
+ 7. Transmission elements
+ 8. Brake system
+ 9. A suspension bracket and a steering
+ 10. A body
+ 11. An electric equipment
+ 12. Electroschemes

4.7.2. Removal and installation
THE GENERAL DATA

The pump of a cooling liquid on 4-cylinder engines

1. A lining
2. The pump
3. A belt
4. A pulley
5. Муфта
6. Крыльчатка
7. A casing 1
8. A casing 2

4-CYLINDER ENGINES

PERFORMANCE ORDER
1. Disconnect the battery from weight and merge cooling liquid (subsection 2.33 see).
2. Remove all belts of hinged units.
3. Remove a casing of the fan and the fan.
4. Remove from the pump a pulley and disconnect hoses (the Pump of a cooling liquid fig. see 4-cylinder engines).
5. Turn away bolts and remove the pump.
6. Carefully clear a demountable plane of a cover of the lining rests.
7. Installation is carried out upside-down. Bolts tighten with the set moment.

ENGINE V6

The pump of the engine of 3,0 l

 
1. An inlet branch pipe
2. The thermostat
3. A lining
4. The pump

The pump of the engine of 3,4 l

 
1. A lining
2. An inlet branch pipe
3. The pump
4. The thermostat
5. Hose N2 of a cooler

Bolts of the pump of the engine of 3,0 l

The inhaling moment:

Bolts And – 15,6 Н.м.,
Bolts In – 16,8 Н.м.

PERFORMANCE ORDER
1. Disconnect the battery from weight and merge cooling liquid.
2. Remove a gear belt.
3. Remove an arm of the generator and remove from the pump the thermostat.
4. Disconnect from the pump hose N2 of a cooler.
5. Turn away bolts and remove the pump (fig. Bolts of the pump 3,0 see). Disconnect hoses.
6. Carefully clear a demountable plane of a cover of the consolidation rests.
7. Installation is carried out upside-down. On a pump plane put the hermetic platen. Bolts tighten with the set moment. Keep in mind that bolts of the pump of the engine have of 3,0 l the different sizes (fig. Bolts of the pump 3,0 see).


On the main page