Opel Kadett E

1984-1991 of release

Repair and car operation



Opel Kadett E
+ 1. The maintenance instruction
+ 2. Weekly checks and service in a way
+ 3. Maintenance service
+ 4. The engine
+ 5. System of cooling, heating and ventilation
+ 6. Fuel and exhaust systems
- 7. Start and gymnastics system
   7.1. A technical characteristics
   7.2. A finding of malfunctions in electric chains
   + 7.3. The accumulator
   + 7.4. The generator
   + 7.5. A starter
   7.6. Replacement of the lock of ignition
   7.7. Removal and installation of the gauge of pressure of oil
   7.8. Removal and installation of the gauge of level of oil on models with 16th valves
   - 7.9. The electric equipment of diesel engines 16D, 16DA, 17D and 17DR
      7.9.1. A technical characteristics
      7.9.2. Removal and accumulator installation
      - 7.9.3. A starter
         7.9.3.1. Removal and starter installation
         - 7.9.3.2. Replacement of brushes of a starter
            7.9.3.2.1. All models - a starter редукционного type
            7.9.3.2.2. A starter with preliminary gearing of gear wheels
      7.9.4. Check of system of preliminary heating
      7.9.5. Replacement of candles накаливания
      7.9.6. Removal and installation of the switch of a control bulb of pressure of oil
      7.9.7. Check, removal and installation of a temperature-sensitive element of the fan of a radiator
      7.9.8. Check of the fan of a radiator
      7.9.9. Removal and installation of the gauge of temperature of a cooling liquid
+ 8. Ignition system
+ 9. Coupling
+ 10. Transmissions and power shafts
+ 11. Brake system
+ 12. A suspension bracket and a steering
+ 13. A body
+ 14. Electric schemes

7.9.3.2. Replacement of brushes of a starter

7.9.3.2.1. All models – a starter редукционного type

Removal

PERFORMANCE ORDER
1. Unscrew fixing screws and uncover a starter.
2. Remove washers from an anchor shaft (the arrow specifies the S-shaped washer).
3. Unscrew two through bolts. Use two counternuts and a wrench for unscrewing of bolts.
4. Uncover and disconnect a wire from the traction relay.
5. Remove the fixing plug and the holder of brushes (it is specified by an arrow).

Replacement of brushes

PERFORMANCE ORDER
1. Clear and examine brushes.
2. Replace brushes if they are worn out more than an admissible limit.
3. Check up a condition пружинок.
4. Take away пружинки deep into holders, having inserted a tube of suitable diameter.

Installation

PERFORMANCE ORDER
1. Installation is made in sequence of return to removal.
2. Fill a cap with greasing and fix it by means of two screws.