Audi 100

1982-1990 of release

Repair and car operation




Audi 100
+ 1.1. Controls and devices
+ 2. Technical characteristics
- 3. Engines
   + 3.1. Four-cylinder engines
   - 3.2. Five-cylinder engines
      3.2.1. Removal and engine installation
      - 3.2.2. Dismantling and engine assemblage
         3.2.2.1. Removal and installation of a head of the block of cylinders
         3.2.2.2. Adjustment and a tension of a belt of a drive of a camshaft
         3.2.2.3. Survey, дефектовка and repair of details of a head of the block
         3.2.2.4. Removal of a camshaft and pushers of valves
         3.2.2.5. Installation of a camshaft and pushers of valves
         3.2.2.6. Removal and installation of valves
         3.2.2.7. Dismantling and assemblage of a drive of a camshaft
         3.2.2.8. Removal and flywheel installation
         3.2.2.9. Removal and installation oil картера
         3.2.2.10. Removal, check and installation of the oil pump
         3.2.2.11. Replacement of epiploons of a cranked shaft
         3.2.2.12. A cranked shaft and shatunno-piston group
   + 3.3. The diesel engine
+ 4. Cooling system
+ 5. An exhaust system
+ 6. The power supply system
+ 7. Transmission
+ 8. A running gear
+ 9. A steering
+ 10. Brake system
+ 11. A body
+ 12. An electric equipment

3.2.2.2. Adjustment and a tension of a belt of a drive of a camshaft
THE GENERAL DATA

Adjustment and check of a tension of a belt of a drive of a camshaft

1 – натяжитель a belt of a drive of a camshaft;

2, 3 – wrenches;

4 – a camshaft cogwheel;

5 – a belt of a drive of a camshaft;

6 – a cogwheel of an intermediate shaft

PERFORMANCE ORDER
1. To turn the water pump counter-clockwise, preliminary having pulled a belt that it has not come off cogwheels. An assembly shovel or a screw-driver to turn the water pump counter-clockwise, having pulled a belt. To tighten bolts of fastening of the water pump.
2. To check up a belt tension. The belt should be overwound no more than on 90 ° by effort of the big and index fingers.
3. Definitively to tighten bolts of fastening of the water pump the moment 20 Н·м (2,0 кгс·м).


On the main page