| Design | Thermosiphon with лопастным the water pump. Thermostatic adjustment. With a separate broad tank. The fan with вязкостной муфтой. The additional electric fan joins and switched off by a thermoswitch |
| Cooling liquid | Mix of soft water (60 %) and антифризного a concentrate (40 %) |
| Antifriznyj concentrate | G12 (Red colour) (do not mix with any another) |
| System volume |
| Engines 1.6, 1.8 l | 5.0 l |
| Concentration of antifreeze in a cooling liquid for maintenance of frost resistance to |
| – 35°С | 50 % |
| – 25°С | 40 % |
| The thermostat |
| Temperature of the beginning of opening | 87°С |
| Temperature of full opening | 102°С |
| Valve stroke | Not less than 7 mm |
| Fan thermoswitch |
|
| Inclusion/deenergizing of 1st step | 92–97/84–91°С |
| Inclusion/deenergizing of 2nd step | 99–105/91–98°С |
| Stopper of a broad tank |
| The valve of superfluous pressure opens | 1.4–1.6 bar |
| The depression valve opens | 0.06–0.1 bar |
| Conditioner coolant |
| Type | R134a |
| Volume, гр. | 750 ± 50 |
| Refrigerator oil |
| Type G052 | 154 A2 |
| Volume, cmi | 135 ± 15 |
| Efforts of a tightening of carving connections |
The moments of an inhaling of fixture are resulted also in the text of the Head and on some иллюстрациях*.
*Выделенные in the text a bold type the inhaling moments are subject to exact observance; the efforts not allocated with a bold type are resulted only roughly
The water pump on the engine |
| Engines | 15 H m |
| Thermostat cover | 15 H m |
| The conditioner compressor | 45 H m |