Citroen Xantia

Since 1993 of release

Repair and car operation



Citroen Xantia
+ Introduction
+ The operation manual
+ Routine maintenance
+ Engine repair
+ Systems of cooling, heating
- The power supply system and release
   + The power supply system - petrol models
   - The power supply system - diesel models
      Filling of the power supply system with fuel and removal from it air stoppers
      Check and adjustment of the maximum turns of the engine
      Removal, installation and adjustment of the thermosensitive gauge of turns of fast idling
      Electromagnetic запорный the valve - the general data, removal and installation
      Removal and installation ТНВД
      Methods of check of installation of the moments of injection of fuel
      Check and adjustment of the moments of injection (ТНВД Lucas)
      Check and adjustment of the moments of injection (ТНВД Bosch)
      Check of serviceability of functioning, removal and installation of atomizers of injection of fuel
      Removal, installation and adjustment of a cable of gas
      Removal and installation of a pedal of gas
      Removal and assemblage installation топливозаборника with the gauge of the expense of fuel
      Removal and installation of a fuel tank
      Removal and installation of the inlet pipeline and final collector
      turbocharger - the general data and safety measures
      Removal and installation турбокомпрессора
      Check of a condition and regenerative repair турбокомпрессора
      Removal and installation of the built in cooler турбокомпрессора
      Removal and installation of an air cleaner and accompanying components
   + Systems of decrease in toxicity and release of the fulfilled gases
+ Engine electric equipment
+ Coupling
+ Transmission
+ Power shafts
+ Uniform hydraulic system
+ Brake system
+ Running gear and steering
+ Body and salon furnish
+ Onboard electric equipment
+ Electric equipment schemes

Electromagnetic запорный the valve - the general data, removal and installation

Try not to admit dirt hit inside ТНВД!

The general information

Protective cap of a contact socket electromagnetic запорного the valve (ТНВД Bosch)

Removal of a protective cap of a contact socket electromagnetic запорного the valve (ТНВД Lucas)

The valve is located end face ТНВД. The valve serves for отсекания fuel givings at ignition deenergizing. At disconnection of the valve or breakage of a wire of its food engine start becomes impossible as fuel simply will not arrive in atomizers. Besides to result results jamming плунжера the valve in position "is locked". If the valve jams in position "openly", останова the engine after ignition deenergizing will not occur.

At refusal запорного the valve temporary start of the engine can be made by valve removal (see more low), extraction from it плунжера with a spring and installations into place without internal components. It is necessary to wind a wire so that it did not adjoin to weight. To muffle the engine after such start it is necessary to take advantage of the lever manual останова on ТНВД (the Power supply system - diesel models see), or to switch off ignition on transfer.

Removal

 PERFORMANCE ORDER

1. Disconnect a negative wire from the battery.
2. On the models equipped ТНВД of system Bosch, for the purpose of providing of access to the valve it is necessary отболтить from a pump wall a basic arm drive a cable of turns of fast idling. The description of procedure of liberation of a cable from an arm is resulted in section Removal, installation and adjustment of the thermosensitive gauge of turns of fast idling.
3. At a corresponding complete set remove a rubber protective cap, then give a fixing nut клеммного connections with the top end face запорного the valve.
4. Carefully wipe клепан outside, then turn out it from the nest in pump assemblage. Remove a sealing washer/ring. If плунжер with a spring remained in pump assemblage, take them therefrom. For washing away of dust from a nest of landing of the valve take advantage of a rubber pear of the pump of manual filling of the power supply system.

Installation

Installation is made upside-down. Do not forget to replace a sealing washer/ring of the valve. Track observance of demanded effort of a tightening.

If the detachment drive a cable of fast idling was made, execute its adjustment (Removal, installation and adjustment of the thermosensitive gauge of turns of fast idling see).