Subaru Legacy/Outback

1999-2003 of release

Repair and car operation



Subaru Legasi, Autbek
+ Cars Subaru Legacy, Outback
+ The operation manual
+ Routine maintenance
+ The engine
- Systems of cooling, heating
   Specifications
   + System of cooling of the engine
   - Heating/ventilation/air conditioning systems
      Removal and installation дефлекторов and air lines
      Removal and installation of resistive assemblage drive the electromotor of the fan of a heater
      Removal, check and installation drive the electromotor of the fan of a heater
      Removal and installation of the control panel by functioning of systems of heating/ventilation/air conditioning
      Removal and installation of assemblage of a heater
      Removal and installation of the heat exchanger of a heater
      Check of serviceability of functioning and service of systems of heating and air conditioning
      Compressor K/V - a design and a functioning principle
      Condenser K/V - a design and a functioning principle
      Receiver-dehumidifier К/В - a design and a functioning principle
      The gauge-switch of pressure К/В - a design and a functioning principle
      Evaporator K/V - a design and a functioning principle
      Broad valve K/V - a design and a functioning principle
      Condition check, removal and installation of the compressor of system K/V
      Removal and installation of the condenser of system K/V
      Removal and installation of a receiver-dehumidifier of system K/V
      Removal and installation of the inlet block of system K/V, evaporator replacement
      Replacement of connecting hoses of a refrigerator path
      Check of serviceability of functioning of the gauge-switch of pressure
      Removal and installation of information gauges of system of an automatic central air (climate control)
+ The power supply system and release
+ Engine electric equipment
+ Manual box and differential
+ Automatic transmission
+ Coupling
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment

The gauge-switch of pressure К/В - a design and a functioning principle

Principle of functioning of the gauge-switch of pressure К/В

1 — Shtyrevaja the plug
2 — Contact points
3 — the Directing pin

4 — the Pusher
5 — the Disk spring of a high pressure
6 — the Disk spring of low pressure


The pressure gauge-switch is included in a line of a high pressure of a receiver-dehumidifier and serves for compressor K/V switching-off at excessive increase or pressure drop in a line.

So pressure lowering in высоконапорной more low 177 кПа the gauge-switch perceives lines as a signal of development of leaks of a coolant and stops the compressor in order to avoid irreversible losses of a working body, the high pressure in a line is excessive (from above 2940 кПа) can lead to destruction of components of a refrigerator path and also demands compressor switching-off.