Subaru Legacy/Outback

1999-2003 of release

Repair and car operation



Subaru Legasi, Autbek
+ Cars Subaru Legacy, Outback
+ The operation manual
+ Routine maintenance
+ The engine
- Systems of cooling, heating
   Specifications
   + System of cooling of the engine
   - Heating/ventilation/air conditioning systems
      Removal and installation дефлекторов and air lines
      Removal and installation of resistive assemblage drive the electromotor of the fan of a heater
      Removal, check and installation drive the electromotor of the fan of a heater
      Removal and installation of the control panel by functioning of systems of heating/ventilation/air conditioning
      Removal and installation of assemblage of a heater
      Removal and installation of the heat exchanger of a heater
      Check of serviceability of functioning and service of systems of heating and air conditioning
      Compressor K/V - a design and a functioning principle
      Condenser K/V - a design and a functioning principle
      Receiver-dehumidifier К/В - a design and a functioning principle
      The gauge-switch of pressure К/В - a design and a functioning principle
      Evaporator K/V - a design and a functioning principle
      Broad valve K/V - a design and a functioning principle
      Condition check, removal and installation of the compressor of system K/V
      Removal and installation of the condenser of system K/V
      Removal and installation of a receiver-dehumidifier of system K/V
      Removal and installation of the inlet block of system K/V, evaporator replacement
      Replacement of connecting hoses of a refrigerator path
      Check of serviceability of functioning of the gauge-switch of pressure
      Removal and installation of information gauges of system of an automatic central air (climate control)
+ The power supply system and release
+ Engine electric equipment
+ Manual box and differential
+ Automatic transmission
+ Coupling
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment

Evaporator K/V - a design and a functioning principle

Principle of functioning of the evaporator

1 — From a receiver-dehumidifier
2 — To the compressor
3 — a suspension of particles of a coolant Close to a liquid state

4 — Steam
5 — the Broad valve


Forced by the fan of a heater air is banished through the heat exchanger of the evaporator and promotes heating moving on the tubes, a liquid coolant being under low pressure. Having reached boiling points, the coolant starts to evaporate intensively, passing in a gaseous state. The moisture containing in a coolant is condensed in drops and together with dirt particles is taken away from system on a special drainage hose.

The evaporator heat exchanger shows the complete set of thin aluminium plates of the squared shape located in some layers, with fixed between them ламелями.

Being in close to liquid a condition the suspension of particles of a coolant through the broad valve under low pressure arrives in the bottom tube of the evaporator and starts to be warmed up intensively. In view of high intensity of heat exchange the coolant quickly reaches boiling points and evaporates. Further, at the expense of developed by bubbles of a carrying power generated during boiling, the coolant rises and gets into the tube of assemblage located above. By the time of hit in the top tank of the evaporator the coolant completely passes in a gaseous state.

The evaporator design differs high durability of execution, stability to influence of corrosion and thermal stability.