On some carburettors the electromagnetic valve of a stopping delivery of fuel is established. It электрически the operated valve which interrupts fuel giving in idling system at ignition deenergizing therefore work of the engine after ignition deenergizing is prevented.
The valve of a stopping delivery of fuel is included all time while ignition is included. If the valve is faulty or to it pressure does not move, the engine will stop or work unstably on idling turns though on higher turns it will work normally.
PERFORMANCE ORDER |
1. At valve check first of all check up that to it pressure moves at ignition inclusion. |
2. Unscrew the valve from the carburettor and connect the case of the valve to the negative plug of the accumulator. At giving of positive pressure of the accumulator on valve contact there should be accurately heard click, thus a needle on a valve tip should be involved. |
3. If the valve is faulty, it is necessary to replace it. |
|
|