Subaru Legacy/Outback1999-2003 of releaseRepair and car operation |
|
Subaru Legasi, Autbek + Cars Subaru Legacy, Outback + The operation manual + Routine maintenance + The engine + Systems of cooling, heating + The power supply system and release - Engine electric equipment Specifications Start of the engine from the auxiliary power supply Removal/installation, check and service of the storage battery Check of a condition and replacement of wires of the battery Ignition system - the general information and safety measures Check of serviceability of functioning of system of ignition Removal, installation and check of a condition of the module (it) of ignition Check and adjustment of installation of a corner of an advancing of ignition Replacement of gauges CKP, CMP and KS Service and replacement of spark plugs Check of a condition of high-voltage wires (4-cylinder engines) Charge system - the general information and safety measures Check of a condition of system of a charge The generator - the general information, check and service Removal, dismantling, assemblage and generator installation Start system - the general information and safety measures Check of serviceability of functioning of a starter and start chain Starter Nippondenso - check and service Starters Mitsubishi - check and service + Manual box and differential + Automatic transmission + Coupling + Brake system + Suspension bracket and steering + Body + Onboard electric equipment |
The generator - the general information, check and service Generator design
For a complete set of considered models generators of an alternating current, company Mitsubishi manufacture are used. On type the given generators concern to three-phase with the built in rectifier. The design and the basic electric scheme of the generator are presented on illustrations. Alternating current straightening is carried out by means of диодной the assemblage consisting of three positive and three negative diodes. The control of target pressure of the generator carries out the built in regulator which also carries out diagnostics functions. Continuous switching of a field winding of the generator by the special transistor provides a constancy of level of target pressure. For the control of serviceability of functioning of the generator the control lamp which is a part of a combination of devices of the car is included in a chain of system of a charge. Number of the most typical refusals causing operation of a control lamp concern: a) the Generator has ceased to give out pressure owing to deterioration of brushes, breakage of a field winding, etc.; b) pressure Given out by the generator exceeds 16В; c) there Was a detachment of electroconducting from the plug In the generator; d) there Was a detachment of electroconducting from generator plug S, - in the present state of affairs the generator will be given out by slightly raised pressure, however the battery remains protected from a recharge at the expense of serviceable functioning of a regulator of pressure. Check and service Diodnaja assemblageCheck of serviceability of a condition of the positive diode
Check of serviceability of a condition of the negative diode
Anchor Статор
Brushes
Bearings
|
On the main page |